What is the function of an explosion relief valve (ERV) in a crankcase?

Crankcase ERV

Crankcase overpressure relief valves have three functions:

(1) Rapidly relieve excess pressure inside the crankcase
(2) Prevent flame inside the crankcase from escaping and causing further damage
(3) Rapidly close after the crankcase pressure is relieved to prevent the air from entering into the crankcase.

Figure: Crankcase overpressure relief valve operation.

The figures show that the relief valves have a light spring that holds the valve tightly against its seat. The pressure inside the crankcase is relieved, and the spring closes the valve automatically. Figures show an image of a properly operating crankcase relief valve. The valve is still closed on the left of the picture while an internal explosion is about to open. On the right, the internal pressure has forced the valve open, compressing the spring while the hot pressurized gas, but not the flame, is vented to the atmosphere. Once the pressure is relieved, the compressed spring closes the valve.

Figure: ERV in the industry.

API 618 requires a relief area to crankcase volume ratio of 3.0 in²/ft³ (683 cm² /m³), which is higher than any of the engine standards. With properly sized and installed overpressure relief valves, experience has shown that the risk of damage and injury from crankcase explosions can be eliminated. Most compressor and engine manufacturers offer them as standard equipment on large machines and options for smaller frame sizes.

Final Words

The crankcase explosion relief valve (ERV) rapidly relieves excess pressure, prevents flame, and rapidly closes after the crankcase pressure is relieved.

More to Read

1. Renewable energy
2. Nuclear energy

Share this on

More to explore

Leave a Comment

Your email address will not be published. Required fields are marked *

Nazrul

About the author of the website: I am AKM Nazrul Islam, currently working in Japan. I have achieved a Master of Science (M.Sc) in Mechanical Engineering from Bangladesh University of Engineering and Technology (BUET). Out of my 12 years of working experience, I worked in the thermal power industry for 7 years, renewable energy industry for 2 years, and research university for 3 years. I have low voltage, medium voltage, and high voltage electrical works licenses. I have published 11 scientific articles. I am a member of the American Society of Mechanical Engineers (ASME), Japanese Society of Mechanical Engineers (JSME), Institute of Engineers Bangladesh (IEB), Bangladesh Solar Energy Society (BSES).